OneConnect Parameters¶
For the TotalviewOneConnect connector to be able to communicate with One-Connect, a user with the roles “Omstillingsbord” and “Tillad Administration” must be created on One-Connect.
Also the PBX setting “Håndfri Kaldhåndtering” must be checked and the TotalviewOneConnect machine IP address must be added to the “Netblokke” section with API access enabled.
Server address |
Address of the One-Connect CSTA server. Default is csta.one-connect.dk |
Port |
The One-Connect CSTA server port. Default is 7001 |
One-Connect user |
Username of the user with the role “Omstillingsbord” |
Password |
Password for the One-Connect user |
PBX-Domain |
The pbx-domain of the customer in the format number.pbx.one-connect.dk |
International prefix |
Usually 00. For example 0045xxxx Denmark and 00298xxxx Faroe Islands. |
International code |
Country code. For example 45 for Denmark and 298 for Faroe Islands |
Local start/end |
Fill in the first and last local number in the connected One-Connect system. All numbers that are not in the interval are treated as external numbers |
Behavior configuration¶
Group filter |
Add a filter to only see groups of interest. If empty then no filtering is added. It’s possible to add an interval of group id’s or individual id’s, e.g. 4000,4010-4020 |
Other settings¶
If using the Uni-tel softphone, the “Accepter automatisk besvarelse” must be enabled on the phone